012-210B NVM Fail RAP
BSD-ON:
BSD 3.6 PWB Communications (ESS PWB/Drive PWB to Finisher)
Procedure
NOTE: Ensure the correct RAP is performed, refer to the
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Check the wiring between the finisher and the IOT.
2.
If the fault persists, install a new finisher PWB,
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
012-210
NVM Fail Entry RAP.
WARNING
PL 13.45 Item
2.
012-211B Stacker Tray Fail RAP
BSD-ON:
BSD 13.15 Office Finisher LX Stacker Tray Control
Initial Actions
NOTE: Ensure the correct RAP is performed, refer to the
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Check for obstructions under the tray.
Check the operation of the stacker height sensor 1,
Check the tray raise/lower mechanism for damage or contamination.
Procedure
Enter
dC330
code 012-264. Actuate the stacker height sensor 1,
play changes.
Y
N
Check the wiring between
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
is approximately +5VDC.
Y
N
Install a new finisher PWB,
Measure the voltage between
the stacker height sensor 1. The voltage changes.
Y
N
Install a new stacker height sensor 1,
Install a new finisher PWB,
Enter
dC330
code 012-263. Manually rotate the encoder,
stacker encoder sensor. The display changes.
Y
N
Check the wiring between
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
is approximately +5VDC.
Y
N
Install a new finisher PWB,
A
B
April 2017
2-83
012-211
Stacker Tray Fail Entry RAP.
WARNING
GP
10. Disconnect the power cord. Electricity can cause
PL 13.27 Item 16
PL 13.27 Item
J8873
pin 2 and
P/J8988
pin 17 for an open or short circuit, or
P/J8988
pins 16 and 18 on the finisher PWB. The voltage
PL 13.45 Item
2.
P/J8988
pin 17 on the finisher PWB and ground. Actuate
PL 13.27 Item
16.
PL 13.45 Item
2.
PL 13.15 Item 19
J8875
pin 2 and
P/J8988
pin 23 for an open or short circuit, or
P/J8988
pins 22 and 24 on the finisher PWB. The voltage
PL 13.45 Item
2.
Status Indicator RAPs
012-210B, 012-211B
actuator.
16. The