Front Cover Interlock Open Entry Rap - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

012-302 Front Cover Interlock Open Entry RAP

012-302 The front cover interlock open was detected.
Procedure
Go to the relevant procedure:
Integrated office finisher installed,
012-302A
Office finisher LX installed,
012-302B
Status Indicator RAPs
012-302, 012-302A
Front Cover Interlock Open RAP.
Front Cover Interlock Open RAP.
012-302A Front Cover Interlock Open RAP
BSD-ON:
BSD 12.1 Integrated Office Finisher DC Power and Interlock Switching
Initial Actions
NOTE: Ensure the correct RAP is performed, refer to the
Entry RAP.
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Check that the front cover can be opened and closed.
Check that the finisher front interlock switch,
undamaged.
Switch off, then switch on the machine,
Procedure
Enter
dC330
code 012-302. Open, then close the front cover to actuate the finisher front inter-
lock switch. The display changes.
Y
N
Check the connections of
P/J8702
Y
N
Secure the connections.
Check for an open or short circuit between
Y
N
Repair the open or short circuit.
Measure the voltage between the finisher PWB
then close the front cover to actuate the finisher front interlock switch. The
changes.
Y
N
Install a new finisher front interlock switch,
Check the wires and connectors for an intermittent open or short circuit. If the fault per-
sists, install a new finisher PWB,
Measure the voltage between the finisher PWB
approximately +24VDC.
Y
N
Check the +24VDC circuit. Refer to the
Check the wires and connectors for an intermittent open or short circuit. If the fault persists,
install a new finisher PWB,
PL 12.14 Item
April 2017
2-74
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
012-302
Front Cover Interlock Open
WARNING
GP
10. Disconnect the power cord. Electricity can cause
PL 12.14 Item 12
is correctly installed and
GP
10.
and P/J8733. The connectors are good.
P/J8702
and P/J8733. The wiring is good.
P/J8702
pin 4 (+) and ground (-). Open,
PL 12.14 Item
12.
PL 12.14 Item
1.
P/J8702
pin 1 (+) and (-). The
Wiring
Diagrams.
1.
voltage
voltage
is
Launch Issue