Stacker Tray Lower Limit Failure Rap - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

A
B
Measure the voltage between
P/J8988
the stacker height sensor 2. The voltage changes.
Y
N
Install a new stacker height sensor 2,
Install a new finisher PWB,
PL 13.45 Item
Enter
dC330
code 012-263. Manually rotate the encoder,
stacker encoder sensor. The display changes.
Y
N
Check the wiring between
J8875
pin 2 and
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
P/J8988
is approximately +5VDC.
Y
N
Install a new finisher PWB,
PL 13.45 Item
Measure the voltage between
P/J8988
rotate the encoder,
PL 13.15 Item 19
changes.
Y
N
Install a new stacker encoder sensor,
Install a new finisher PWB,
PL 13.45 Item
Enter
dC330
code 012-262. Actuate the stacker paper sensor,
play changes.
Y
N
Check the wiring between
J8872
pin 2 and
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
P/J8988
is approximately +5VDC.
Y
N
Install a new finisher PWB,
PL 13.45 Item
Measure the voltage between
P/J8988
the stacker no paper sensor The voltage changes.
Y
N
Install a new stacker no paper sensor,
Install a new finisher PWB,
PL 13.45 Item
Install a new finisher PWB,
PL 13.45 Item
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
pin 20 on the finisher PWB and ground. Actuate
PL 13.27 Item
16.
2.
PL 13.15 Item 19
to actuate the
P/J8988
pin 23 for an open or short circuit, or
pins 22 and 24 on the finisher PWB. The voltage
2.
pin 23 on the finisher PWB and ground. Manually
to actuate the stacker encoder sensor. The voltage
PL 13.15 Item
32.
2.
PL 13.15 Item
32. The
P/J8988
pin 14 for an open or short circuit, or
pins 13 and 15 on the finisher PWB. The voltage
2.
pin 14 on the finisher PWB and ground. Actuate
PL 13.15 Item
32.
2.
2.

012-213 Stacker Tray Lower Limit Failure RAP

BSD-ON:
BSD 13.15 Office Finisher LX Stacker Tray Control
012-213 Stacker descended lower than normal levels, below low limit height.
Initial Actions
Check for obstructions under the tray.
Check the operation of the stacker height sensor,
Check the tray raise/lower mechanism for damage or contamination.
Procedure
Enter
dC330
code 012-264. Actuate the stacker height sensor 1. The display changes.
Y
N
Check the wiring between
J8873
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
is approximately +5VDC.
Y
N
Install a new finisher PWB,
Measure the voltage between
the stacker height sensor 1. The voltage changes.
Y
N
dis-
Install a new stacker height sensor 1,
Install a new finisher PWB,
Enter
dC330
code 012-265. Actuate the stacker height sensor 2. The display changes.
Y
N
Check the wiring between
J8874
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
is approximately +5VDC.
Y
N
Install a new finisher PWB,
Measure the voltage between
the stacker height sensor 2. The voltage changes.
Y
N
Install a new stacker height sensor 2,
Install a new finisher PWB,
A
April 2017
2-85
PL 13.27
actuators.
pin 2 and
P/J8988
pin 17 for an open or short circuit, or
P/J8988
pins 16 and 18 on the finisher PWB. The voltage
PL 13.45 Item
2.
P/J8988
pin 17 on the finisher PWB and ground. Actuate
PL 13.27 Item
16.
PL 13.45 Item
2.
pin 2 and
P/J8988
pin 20 for an open or short circuit, or
P/J8988
pins 19 and 21 on the finisher PWB. The voltage
PL 13.45 Item
2.
P/J8988
pin 20 on the finisher PWB and ground. Actuate
PL 13.27 Item
16.
PL 13.45 Item
2.
Status Indicator RAPs
012-212, 012-213

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versalink b7030Versalink b7035

Table of Contents