Drive Pwb Communication Fail Rap - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

057-310, 057-312 Drive PWB Communication Fail RAP

057-310 SPI communication data abnormality between the drive PWB and the ESS PWB.
057-312 SPI communication data abnormality between the drive PWB and the ESS PWB
Procedure
Perform the
045-311, 045-396
Controller Communication Fail RAP.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
057-311, 313, 314, 315 Drive PWB Fail RAP
057-311 Abnormality in the WDT circuit that monitors the SPI communication status in which
the drive PWB is mounted.
057-313 Drive PWB fuse 13 open circuit was detected.
057-314 Drive PWB fuse 14 open circuit was detected.
057-315 Drive PWB fuse 15 open circuit was detected.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
1.
Switch off, then switch on the machine,
2.
If the fault persists, install a new drive PWB,
April 2017
057-310, 057-312, 057-311, 313, 314, 315
2-455
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
PL 1.10 Item
3.