116-383 PIT Lib Failure RAP
116-383 Board Fault/non-installation, or HDD access error.
Procedure
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Check
dC125
Active Faults. If a new fault is listed, perform the relevant RAP.
3.
If the fault persists, perform the
016-210, 506, 777, 780, 798
Status Indicator RAPs
116-383, 116-384, 385, 387, 389
GP
10.
HDD Error RAP.
116-384, 385, 387, 389 DCS/IDC Software Fail RAP
116-384 DCS-related fatal error. Due to an error in software processing, subsequent pro-
cesses cannot be performed.
116-385 Fatal error related to IDC. Due to an error in software processing, subsequent pro-
cesses cannot be performed.
116-387 A fatal error has occurred during the usage of high compression board.
116-389 The necessary additional RAM was not installed.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Ensure that all connectors on the drive PWB,
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP
4.
4.
Perform the
OF2
Special Boot Modes RAP.
April 2017
2-514
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10.
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Launch Issue