A
Y
N
Install a new eject home sensor,
Check the wires and connectors for an intermittent open or short circuit. If the fault per-
sists, install a new finisher PWB,
PL 12.14 Item
Enter
dC330
code 012-054 and 012-056 alternately. The eject motor runs.
Y
N
Check the connections of
P/J8706
and P/J8741. The connectors are good.
Y
N
Secure the connections.
Check for an open or short circuit between
Y
N
Repair the open or short circuit.
Measure the voltage between the finisher PWB
between
P/J8706
pin 15 (+) and ground (-). The voltage is approximately +24VDC.
Y
N
Check the +24VDC circuit. Refer to the
Check the eject motor drive mechanism for deformed parts, broken parts, and/or belt
damage The drive mechanism is good.
Y
N
Repair defects or damage to the drive mechanism. Install new components as nec-
essary,
PL
12.25.
Install a new eject motor,
PL 12.25 Item
PWB,
PL 12.14 Item
1.
Check the wires and connectors for an intermittent open or short circuit. If the fault persists,
install a new finisher PWB,
PL 12.14 Item
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
PL 12.26 Item
9.
1.
P/J8706
and P/J8741. The wiring is good.
P/J8706
pin 13 (+) and ground (-), and
Wiring
Diagrams.
15. If the fault persists, install a new finisher
1.
012-210 NVM Fail Entry RAP
012-210 An error is detected at NVM access.
Procedure
Go to the relevant procedure:
•
Integrated office finisher installed,
•
Office finisher LX installed,
012-210B
April 2017
2-63
012-210A
NVM Fail RAP.
Stacker Tray Fail RAP.
Status Indicator RAPs
012-161A, 012-210