041-310 IM Logic Fail RAP

BSD-ON:
BSD 3.1 PWB Communications (ESS PWB to Drive PWB)
041-310 IM software control error detected.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Reload the software,
GP
4.
3.
If the fault persists, install new components as necessary:
Drive PWB,
PL 1.10 Item
3.
ESS PWB,
PL 3.10 Item
6.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10.
041-333 Drive PWB F10 Blown RAP
BSD-ON:
BSD 1.5 DC Power Generation (2 of 2)
BSD-ON:
BSD 1.7 Option DC Power Distribution
041-333 Drive PWB fuse 10 open circuit was detected.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Check the tray module for overcurrent and overvoltage. Repair the wiring or install new
components as necessary.
2.
After the faulty circuit has been repaired, install a new drive PWB,
April 2017
2-443
WARNING
GP
10. Disconnect the power cord. Electricity can cause
PL 1.10 Item
Status Indicator RAPs
041-310, 041-333
3.