124-313, 124-356 DC132 Error 10 RAP

124-313 Stored data mismatch. The serial numbers do not match.
124-356 Serial number 1 point mismatch.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Switch off, then switch on the machine,
Y
N
Perform
SCP 5
Final Actions.
Enter
dC132
Device ID and Billing Data. All three serial numbers are different.
Y
N
Install a new drive PWB,
PL 1.10 Item 3
Perform dC132. Make all three serial numbers the same.
Status Indicator RAPs
124-313, 124-356, 124-315, 317, 355
WARNING
GP
10. The fault persists.
and ESS PWB,
PL 3.10 Item
6.
124-315, 317, 355 DC132 Error 02, 04 and 14 RAP
124-315 Stored data mismatch. Internal control error was detected.
124-317 Stored data mismatch. Internal control error was detected.
124-355 At least one set of territory information at the 3 locations is different.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Switch off, then switch on the machine,
Y
N
Perform
SCP 5
Final Actions.
Enter dC131. Compare NVM values 700-600, 700-601 and 700-602. All three values are dif-
ferent.
Y
N
Install a new drive PWB,
PL 1.10 Item 3
Perform dC132. Make all three values the same.
April 2017
2-558
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10. Disconnect the power cord. Electricity can cause
GP
10. The fault persists.
and ESS PWB,
PL 3.10 Item
6.
Launch Issue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versalink b7030Versalink b7035

Table of Contents