Drive Pwb Nvm (Eeprom) Fail Rap - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

041-340, 041-341 Drive PWB NVM (EEPROM) Fail RAP

BSD-ON:
BSD 3.1 PWB Communications (ESS PWB to Drive PWB)
041-340 NVM (EEPROM) data abnormality.
041-341 NVM (EEPROM) access error.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Fault code 041-340 Only. Enter dC131. Check that the NVM values that follow are set to 0:
740-016 Range Over Chain No
740-017 Range Over Link No
740-018 Range Over Chain Link
740-019 Range Over Value
740-020 Write in Progress Range Over Chain No
740-021 Write in Progress Range Over Link No
Procedure
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
Reload the software,
GP
4.
3.
dC301
NVM Initialization.
4.
If the fault persists, install new components as necessary:
Drive PWB,
PL 1.10 Item
3.
ESS PWB,
PL 3.10 Item
6.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10.
041-371 Productivity Not Set RAP
041-371 Productivity not set.
Procedure
Perform the steps that follow:
1.
Switch off, then switch on the machine,
2.
If the fault persists, perform dC132.
April 2017
2-445
GP
10.
Status Indicator RAPs
041-340, 041-341, 041-371