060-344 to 060-356 LPH Fault RAP

BSD-ON:
BSD 6.4 Laser Control
060-344 Large pixel count error between the video output and LPH. Image abnormality may
occur.
060-348 Communication error between ESS and LPH. Possibly caused by an external noise.
060-352 LPH reset due to a noise was detected. Possibly caused by an external noise.
060-356 Large pixel count error between the video output and LPH. Image abnormality may
occur.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
1.
Switch off, then switch on the machine,
2.
Check the connections and ribbon cable between the LPH and the ESS PWB ( P/J1363).
3.
If the fault persists, install new components as necessary:
Print head assembly,
PL 60.35 Item
FFC ribbon cable,
PL 60.35 Item
ESS PWB,
PL 3.10 Item
6.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
GP
10.
1.
9.
061-357, 365, 369, 373, 393 LPH Communications Fault
RAP
061-357 ASIC register error in IBY initial DL check. It may be an error in the LPH (ASIC or
memory). It may also be an ASIC malfunction due to poor power supply or a communication
error due to poor connection with the ESS.
061-365 Communication error between ESS and LPH (data read error from LPH). It may occur
due to external noise, poor connection of FFC, poor power supply, etc.
061-369 Communication error between ESS and LPH (data write error to LPH). It may occur
due to an external noise, poor connection of FFC, poor power supply, etc.
061-373 Communication error between ESS and LPH (error in the communication IC or cable).
It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-393 Large pixel count error between the video output and LPH. Image abnormality may
occur.
Procedure
Perform the
060-344 to 060-356
April 2017
060-344 to 060-356, 061-357, 365, 369, 373, 393
2-461
LPH Fault RAP.