Front Tamper Home Sensor Fail Entry Rap - Xerox VersaLink B7025 Service Manual

Hide thumbs Also See for VersaLink B7025:
Table of Contents

Advertisement

B
Y
N
Secure the connections.
Check for an open or short circuit between
Y
N
Repair the open or short circuit.
Enter
dC330
code 012-060. Measure the voltage between the finisher PWB
1 (+) and ground (-). The voltage changes.
Y
N
Check the +24VDC circuit. Refer to the
a new finisher PWB,
PL 12.14 Item
Enter
dC330
code 012-061. Measure the voltage between the finisher PWB
2 (+) and ground (-). The voltage changes.
Y
N
Check the +24VDC circuit. Refer to the
a new finisher PWB,
PL 12.14 Item
Check the wires and connectors for an intermittent open and short circuit. If the fault per-
sists, install a new stacker motor,
PL 12.20 Item
Check the wires and connectors for an intermittent open or short circuit. If the fault persists,
install a new finisher PWB,
PL 12.14 Item
Status Indicator RAPs
012-211A, 012-221, 012-223
P/J8711
and P/J8736. The wiring is good.
P/J8711
Wiring
Diagrams. If the fault persists, install
1.
P/J8711
Wiring
Diagrams. If the fault persists, install
1.
9.
1.
012-221, 012-223 Front Tamper Home Sensor Fail Entry
RAP
012-221 The front tamper home sensor failed to actuate within the specified time.
012-223 The front tamper home sensor failed to deactuate within the specified time.
pin
Procedure
Go to the relevant procedure:
Integrated office finisher installed,
RAP
Office finisher LX installed,
012-221B, 012-223B
pin
April 2017
2-66
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
012-221A, 012-223A
Front Tamper Home Sensor Fail.
Front Tamper Home Sensor Fail RAP.
Launch Issue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versalink b7030Versalink b7035

Table of Contents