Chapter 8 Parameters

P3-xx Communication Parameters

P3-00●
ADR
Operational
Interface:
Default: 0x7F
Control
Mode:
Range: 0x01 ~ 0x7F
Data Size: 16-bit
Format: Hexadecimal
Settings: The communication address setting is divided into Y, X (hexadecimal):
8-136
Address Setting
Panel / Software
ALL
Unit: -
Range
When using RS-232/RS-485 to communicate, one servo drive can only
set one address. The duplicate address setting will cause abnormal
communication.
This address represents the absolute address of the servo drive in
communication network. It is also applicable to RS-232, RS-485,
CANopen and DMCENT.
When the communication address setting of MODBUS is set to 0xFF,
the servo drive will automatically reply and receive data regardless of
the address. However, P3-00 cannot be set to 0xFF.
Communication
0
0
Address: 0300H
0301H
Related Section:
9.2
Y
X
0 ~ 7
0 ~ F
Revision February, 2017