Chapter 7 Parameters

P3-xx Communication Parameters

P3-00●
ADR
Operation
Interface:
Default: 0x7F
Control
Mode:
Range: 0x01 ~ 0x7F
Data Size: 16-bit
Format: Hexadecimal
Settings: The communication address setting is divided into Y, X
P3-01
BRT
Operation
Interface:
Default: 0x0033
Control
Mode:
Range: 0x0000 ~ 0x0055
Data Size: 16-bit
Format: Hexadecimal
Settings: The setting of transmission speed is divided into Z, Y, X
7-80
Address Setting
Panel / Software
ALL
Unit: N/A
(hexadecimal):
Display
Range
When using RS-232 / RS-485 to communicate, one servo drive
can only set one address. The duplicate address setting will cause
abnormal communication.
This address represents the absolute address of the servo drive in
communication network. It is also applicable to RS-232 / 485 and
CAN bus.
When the communication address setting of MODBUS is set to
0xFF, the servo drive will automatically reply and receive data
regardless of the address. However, P3-00 cannot be set to 0xFF.
Transmission Speed
Panel / Software
ALL
Unit: bps
(hexadecimal):
COM Port
Range
Communication
0
0
-
-
Communication
0
Z
-
-
0
0
Address: 0300H
0301H
Related Section:
8.2
Y
X
0 ~ 7
0 ~ F
Address: 0302H
0303H
Related Section:
8.2
Y
X
RS-485
RS-232
0 ~ 5
0 ~ 5