Settings: 1~50Hz: Low stiffness, low response
NOTE
P2-32▲
AUT2
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 0x2
Data Size: 16-bit
Format: Hexadecimal
Settings: 0: Manual Mode
Revision February, 2017
51~250Hz: Medium stiffness, medium response
251~850Hz: High stiffness, high response
851~1000Hz: Extremely high stiffness, extremely high response
1)According to the speed loop setting of P2-31, the servo drive sets
the position loop response automatically.
2)The function is enabled via parameter P2-32. Please refer to
Chapter 5.6 for corresponding bandwidth size of the setting value.
Tuning Mode Selection
Panel / Software
ALL
Unit: -
1: Auto Mode (continuous adjustment)
2: Semi-auto Mode (non- continuous adjustment)