ASDA-A2
P1-55
MSPD Maximum Speed Limit
Operational
Interface:
Default: Same as the rated speed of each model
Control
Mode:
Range: 0 ~ max.speed
Data Size: 16-bit
Format: Decimal
Settings: The default of the max. speed of servo motor is set to the rated speed.
P1-56
OVW
Operational
Interface:
Default: 120
Control
Mode:
Range: 0 ~ 120
Data Size: 16-bit
Format: Decimal
Settings: The setting value is 0 ~ 100, if the servo motor continuously outputs
P1-57
CRSHA Motor Crash Protection (torque percentage)
Operational
Interface:
Default: 0
Control
Mode:
Revision February, 2017
Panel / Software
ALL
Unit: r/min
Output Overload Warning Level
Panel / Software
ALL
Unit: %
the load and is higher than the setting proportion (P1-56), the early
warning for overload (DO is set to 10, OLW) will occur.
If the setting value is over 100, it will disable this function.
Panel / Software
ALL
Communication
Communication
Communication
Chapter 8 Parameters
Address: 016EH
016FH
Related Section: -
Address: 0170H
0171H
Related Section: -
Address: 0172H
0173H
Related Section: -
8-79