Delta ASD-A2 Series User Manual page 365

Table of Contents

Advertisement

Chapter 8 Parameters
P2-45
NCF3
Operational
Interface:
Default: 1000
Control
Mode:
Range: 50 ~ 2000
Data Size: 16-bit
Format: Decimal
Settings: The third group of mechanism resonance frequency setting value. If
P2-46
DPH3
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 32
Data Size: 16-bit
Format: Decimal
Settings: The third group of resonance suppression (Notch filter) attenuation
P2-47
ANCF Auto Resonance Suppression Mode Setting
Operational
Interface:
Default: 1
Control
Mode:
8-114
Resonance Suppression (Notch filter) (3)
Panel / Software
ALL
Unit: Hz
P2-46 is set to 0, this function will be disabled. P2-23 and P2-24 are
the first group of resonance suppression (Notch filter).
Resonance Suppression (Notch filter)
Attenuation Rate (3)
Panel / Software
ALL
Unit: dB
rate. Set the value to 0 to disable the function of Notch filter.
Panel / Software
ALL
Communication
Communication
Communication
ASDA-A2
Address: 025AH
025BH
Related Section:
6.3.7
Address: 025CH
025DH
Related Section:
6.3.7
Address: 025EH
025FH
Related Section: -
Revision February, 2017