Chapter 8 Parameters
P1-29
AVSM
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1
Data Size: 16-bit
Format: DEC
Settings: 0: The function is disabled.
P1-30
VCL
Operational
Interface:
Default: 500
Control
Mode:
Unit: Pulse
Range: 1 ~ 8000
Data Size: 16-bit
Format: Decimal
Settings: When enabling the auto suppression (P1-29 = 1), it will automatically
8-64
Auto Low-frequency Vibration Supression
Setting
Panel / Software
PT / PR
Unit: -
1: The value will set back to 0 after vibration suppression.
Description of Auto Mode Setting:
When the parameter is set to 1, it is in auto suppression. When the
vibration frequency is not being detected or the value of searched
frequency is stable, the parameter will set to 0 and save the low-
frequency vibration suppression to P1-25 automatically.
Low-frequency Vibration Detection
Panel / Software
PT / PR
search the detection level. The lower the value is, the more sensitive
the detection will be. However, it is easy to misjudge the noise or
regard the other low-frequency vibration as the suppression frequency.
If the value is bigger, it will make more precise judgment. However, if
the vibration of the mechanism is smaller, it might not detect the
frequency of low-frequency vibration.
Communication
Communication
ASDA-A2
Address: 013AH
013BH
Related Section:
6.2.9
Address: 013CH
013DH
Related Section:
6.2.9