Chapter 7 Motion Control
CAP trigger
Other
E-CAM disengage
trigger
Revision February, 2017
communication.
After the capture is completed, procedure #50 can be
triggered and activated by the setting value Bit3 of P5-39 X.
When E-cam is disengaged and returns to PR mode, the
procedure specified by P5-88 BA setting value can be
triggered.
A2L does not support E-Cam function.