Delta ASD-A2 Series User Manual page 609

Table of Contents

Advertisement

ASDA-A2
ECMA Series
Brake release time
[ms (Max)]
Brake pull-in time
[ms (Max)]
Vibration grade (μm)
Operating temperature (
o
Storage temperature (
Operating humidity
Storage humidity
Vibration capacity
IP Rating
Approvals
Note:
*1
The rated torque is the continuous permissible torque between 0~40˚C operating temperature which
is suitable for the following heat sink dimension.
ECMA-__04 / 06 / 08 : 250 mm x 250 mm x 6 mm
ECMA-__10 : 300 mm x 300 mm x 12 mm
ECMA-__13 : 400 mm x 400 mm x 20 mm
ECMA-__18 : 550 mm x 550 mm x 30 mm
ECMA-__22 : 650 mm x 650 mm x 35 mm
Material: Aluminum – F40, F60, F80, F100, F130, F180, F220
*2
The built-in brake of the servo motor is for remaining the item in stop status. Do not use it to
decelerate or as the dynamic brake.
11-12
E△ 13
05
10
15
10
10
10
70
70
70
o
C)
C)
IP65 (use the waterproof connector and shaft seal installation (or oil seal) model)
E△ 18
20
20
30
10
10
10
70
70
70
15
o
o
0
C to 40
C
o
o
-10
C to 80
C
20% to 90% RH (non-condensing)
20% to 90% RH (non-condensing)
2.5 G
Chapter 11 Specifications
G△ 13
35
03
06
10
10
10
70
70
70
Revision February, 2017
09
10
70

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents