Delta ASD-A2 Series User Manual page 595

Table of Contents

Advertisement

ASDA-A2
:Enter the incorrect password when using
AL132
CANopen PDO
:Heartbeat or NodeGuarding error
AL170
:Heartbeat or NodeGuarding error
AL180
:Abnormal CAN Bus hardware
AL185
:CAN bus off
AL186
:An error occurs when loading CANopen
AL201
data
:Parameter group of PR#8 is out of range
AL207
:Parameter number of PR#8 is out of range
AL209
:An error occurs when writing parameter via
AL213
PR:exceeds the range
:An error occurs when writing parameter via
AL215
PR:read-only
:An error occurs when writing parameter via
AL217
PR:parameter locked
:The setting of monitor item of PR#8 is out
AL231
of range
:PR command overflows
AL235
:Indexing coordinate is undefined
AL237
:Forward Software Limit
AL283
:Reverse Software Limit
AL285
:Feedback position counter overflows
AL289
:Servo Off error
AL291
10-32
Chapter 10 Troubleshooting
NMT: Reset node or 0x6040.Fault
Reset
NMT: Reset node or 0x6040.Fault
Reset
NMT: Reset node or 0x6040.Fault
Reset
NMT: Reset node or re-servo on
NMT: Reset node or 0x6040.Fault
Reset
Turn DI.ARST on to clear the alarm.
CANopen 0x1011 Restore default
parameter
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
DI.Alm Reset or P0-01 = 0
DI.Alm Reset or P0-01 = 0
Re-adjust PR command and parameter
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
NMT: Reset node or 0x6040.Fault
Reset
1. Turn DI.ARST on to clear the
alarm.
2. Set P0-01 to 0.
NMT: Reset node or 0x6040.Fault
Reset
NMT: Reset node or 0x6040.Fault
Reset
NMT: Reset node or 0x6040.Fault
Reset
NMT: Reset node or 0x6040.Fault
Reset
Revision February, 2017