P3-Xx Communication Parameters - Delta ASD-A2R-0221 Series User Manual

Asda-a2r series a high performance with diverse communication interfaces servo drive
Table of Contents

Advertisement

P3-xx Communication Parameters

P3-00●
ADR
Operational
Interface:
Default: 0x7F
Control
Mode:
Unit: -
Range: 0x01 ~ 0x7F
Data Size: 16bit
Format: HEX
Settings: The communication address setting is divided into Y, X
P3-01
BRT
Operational
Interface:
Default: 0x0203
Control
Mode:
Unit: bps
Range: 0x0000 ~ 0x0405
Data Size: 16bit
Format: HEX
Revision December, 2014
Address Setting
Panel / Software
ALL
(hexadecimal):
0
Range
When using RS-232/RS-485 to communicate, one servo drive
can only set one address. The duplicate address setting will
cause abnormal communication.
This address represents the absolute address of the servo drive
in communication network. It is also applicable to RS-232/485
and CAN bus.
When the communication address setting of MODBUS is set to
0xFF, the servo drive will automatically reply and receive data
regardless of the address. However, P3-00 cannot be set to 0xFF.
Transmission Speed
Panel / Software
ALL
Chapter 8 ParametersASDA-A2R Series
Communication
0
Y
0 ~ 7
Communication
Address: 0300H
0301H
Related Section:
9.2
X
0 ~ F
Address: 0302H
0303H
Related Section:
9.2
8-119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents