ASDA-A2
P5-81
ECHD E-CAM: Start Address of Data Array
Operational
Interface:
Default: 100
Control
Mode:
Range: 0 ~ (800-P5-82)
Data Size: 16-bit
Format: Decimal
Settings: The first data of E-Cam table is saved in the address of data array.
NOTE
P5-82
ECMN E-CAM: Area Number N (at least >=5)
Operational
Interface:
Default: 5
Control
Mode:
Range: 5 ~ 720, must < = (P5-10-P5-81)
Data Size: 16-bit
Format: Decimal
Settings: It means the E-Cam curve is divided into N area, and the table should
NOTE
Revision February, 2017
Panel / Software
PR
Unit: -
1. Version V1.015 (before): This parameter cannot be modified when
E-Cam is activated (P5-88, X = 1).
2. Version V1.015 (included or after): This parameter can be set
anytime, but will be effective only when pre-engaged → engaged.
3. A2L does not support this function.
Panel / Software
PR
Unit: -
And P5-82 x P5-84 <= 2147483647
include N+1 data.
1. This parameter can be wrote when E-Cam stops (Please refer
toP5-88, X=0).
2. A2L does not support E-Cam function.
Communication
Communication
Chapter 8 Parameters
Address: 05A2H
05A3H
Related Section:
7.11
Address: 05A4H
05A5H
Related Section:
7.11
8-201