Chapter 8 Parameters
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: Please refer to parameter P0-03 for the setting of analog output
P1-06
SFLT
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1000 (0: disable this function)
Data Size: 16-bit
Format: Decimal
Settings: 0: Disabled
P1-07
TFLT
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ 1000 (0: disable this function)
Data Size: 16-bit
Format: Decimal
Settings: 0: Disabled
8-48
Unit: % (full scale)
selection.
For example: P0-03 = 0x00 (MON2 is the speed analog output)
When the output voltage value of MON2 is V2: Motor speed = (Max. ×
V2/8) × P1-05/100
Analog Speed Command (Low-pass Filter)
Panel / Software
S
Unit: ms
Analog Torque Command (Low-pass Filter)
Panel / Software
T
Unit: ms
Communication
Communication
ASDA-A2
Address: 010CH
010DH
Related Section:
6.3.3
Address: 010EH
010FH
Related Section:
6.4.3
Revision February, 2017