Delta ASD-A2 Series User Manual page 128

Table of Contents

Advertisement

Chapter 4 Panel Display and Operation
P0-02 Setting
Monitor Displayed
Value
Symbol
17
18
19
20
21
22
23
24
25
26
Example of the displayed
value
(Dec)
(Hex)
(Dec high)
(Dec low)
Revision February, 2017
Resonance frequency (Low byte is the first
resonance and high byte is the second one).
The absolute pulse number of encoder Z phase
equals to the homing value, 0. It will be +5000 or -
5000 pulse when rotating in forward or reverse
direction.
Mapping parameter #1: shows the content of
parameter P0-25
(specify the mapping target by P0-35)
Mapping parameter #2: shows the content of
parameter P0-26
(specify the mapping target by P0-36)
Mapping parameter #3: shows the content of
parameter P0-27
(specify the mapping target by P0-37)
Mapping parameter #4: shows the content of
parameter P0-28
(specify the mapping target by P0-38)
Monitor variable #1: shows the content of parameter
P0-09
(specify the monitor variable code by P0-17)
Monitor variable #2: shows the content of parameter
P0-10
(specify the monitor variable code by P0-18)
Monitor variable #3: shows the content of parameter
P0-11
(specify the monitor variable code by P0-19)
Monitor variable #4: shows the content of parameter
P0-12
(specify the monitor variable code by P0-20)
If the value is 1234, it displays 01234 (shows in decimal
format).
16 bits
If the value is 0x1234, it displays 1234 (shows in
hexadecimal format; the first digit does not show any).
If the value is 1234567890, the display of the high byte is
32 bits
1234.5 and displays 67890 as the low byte (shows in
decimal format).
Description
Status Description
ASDA-A2
Unit
[Hz]
-
-
-
-
-
-
-
-
-
4-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents