Delta ASD-A2 Series User Manual page 379

Table of Contents

Advertisement

Chapter 8 Parameters
P2-70
MRS
Operational
Interface:
Default: 0x0
Control
Mode:
Range: 0x00 ~ 0x07
Data Size: 16-bit
Format: Hexadecimal
Settings:
8-128
operated as incremental motor.
1: Absolute mode. (This setting is only available for the servo motor
with absolute encoder. When an incremental servo motor is
connected, AL069 will occur.)
Y: Setup the pulse command when absolute position is lost
0: When AL060 or AL06A occurs, it cannot accept pulse command
1: When AL060 or AL06A occurs, it can accept pulse command
Z: Function setting when index coordinates overflow
0: Index coordinates is lost when overflows
1: Index coordinates will not overflow, but absolute coordinates will not
remain
U: Reserved
NOTE
This parameter is effective only after the servo drive is re-powered on.
Read Data Format Selection
Panel / Software
ALL
Unit: N/A
Bit7
Bit6
Bit15
Bit14
Bit 0: Data unit setting of digital input/output (DI/DO);
1: Pulse, 0: PUU
Bit 1: Communication data unit setting; 1: Pulse, 0: PUU
Bit 2: Overflow warning; 1: No overflow warning, 0: Overflow warning,
AL.289 (PUU), AL.062 (pulse).
Bit 3 ~ Bit15: Reserved. Must be set to 0 .
Communication
Bit5
Bit4
Bit3
Bit13
Bit12
Bit11
ASDA-A2
Address: 028CH
028DH
Related Section: N/A
Bit2
Bit1
Bit0
Bit10
Bit9
Bit8
Revision February, 2017