ASDA-A2
Settings:
P1-04
MON1 MON1 Analog Monitor Output Proportion
Operational
Interface:
Default: 100
Control
Mode:
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: Please refer to parameter P0-03 for the setting of analog output
P1-05
MON2 MON2 Analog Monitor Output Proportion
Operational
Interface:
Default: 100
Control
Mode:
Revision February, 2017
Polarity of monitor analog output
0: MON1(+), MON2(+)
1: MON1(+), MON2(-)
Polarity of encoder pulse output
0: Forward output
Panel / Software
ALL
Unit: % (full scale)
selection.
For example:
P0-03 = 0x00 (MON1 is the speed analog output)
When the output voltage value of MON1 is V1:
Motor speed = (Max. speed × V1/8) × P1-04/100
Panel / Software
ALL
Polarity of monitor analog output
Polarity of encoder pulse output
Not in use
2: MON1(-), MON2(+)
3: MON1(-), MON2(-)
1: Reverse output
Communication