Delta ASD-A2 Series User Manual page 314

Table of Contents

Advertisement

ASDA-A2
P1-27
VSF2
Operational
Interface:
Default: 1000
Control
Mode:
Range: 10 ~ 1000
Data Size: 16-bit
Format: Decimal
Example: 150 = 15 Hz
Settings: The setting value of the second low-frequency vibration suppression. If
P1-28
VSG2 Low-frequency Vibration Suppression Gain (2)
Operational
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0 ~ 9 (0: Disable the second low-frequency
Data Size: 16-bit
Format: Decimal
Settings: The second low-frequency vibration suppression gain. The bigger value
Revision February, 2017
Low-frequency Vibration Suppression (2)
Panel / Software
PT / PR
Unit: 0.1 Hz
P1-28 is set to 0, then it will disable the second low-frequency filter.
Panel / Software
PT / PR
filter)
it is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested to
set the value to 1.
Communication
Communication
Chapter 8 Parameters
Address: 0136H
0137H
Related Section:
6.2.9
Address: 0138H
0139H
Related Section:
6.2.9
8-63