Chapter 8 Parameters
P2-10
DI1
Operational
Interface:
Default: 101
Control
Mode:
Range: 0 ~ 0x015F (the last two codes are DI code)
Data Size: 16-bit
Format: Hexadecimal
Settings:
P2-11
DI2
Operational
Interface:
Default: 104
Control
Mode:
Range: 0 ~ 0x015F (the last two codes are DI code)
Data Size: 16-bit
8-96
DI1 Functional Planning
Panel / Software
ALL
Unit: -
Input function selection: Please refer to table 8.1
Input contact: a or b contact
0: Set the input contact as normally closed (b contact)
1: Set the input contact as normally opened (a contact)
(P2-10 ~ P2-17) The setting value of function programmed
When parameters are modified, please re-start the servo drive to
ensure it can work normally.
Note: Parameter P3-06 is used to set how digital inputs (DI) accepts
commands, through external terminal or the communication
which determined by P4-07.
DI2 Functional Planning
Panel / Software
ALL
Unit: -
Communication
Input function selection
Input contact
Not in use
Communication
ASDA-A2
Address: 0214H
0215H
Related Section:
Table 8.1
Address: 0216H
0217H
Related Section:
Table 8.1
Revision February, 2017