ASDA-A2
Installation Notes:
1. Check if the power and wiring among R, S, T and DC24V, DC0V
Please refer to Chapter 11 for Specifications. Make sure the input voltage is correct, or it might
damage the servo drive or danger may occur.
2. Check if the output terminal U, V, W of the servo motor is correctly wired. The incorrect wiring
may disable the operation of the motor or cause the malfunction.
3. When applying to the external regenerative resistor, the contact between P
opened and the external regenerative resistor should connect to terminal P
applying to the internal regenerative resistor, the contact between P
and the contact between P
4. When an alarm occurs or the system is in emergency stop status, use ALARM or WARN to
output and disconnect the power of magnetic contactor in order to disconnect the power of
servo drive.
Revision February, 2017
and C should be opened.
Chapter 3 Wiring
are correct.
and D should be
and C. When
and D should be closed
3-15