ASDA-A2
P5-85
ECME E-CAM: Number of Area
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ (P5-82-1)
Data Size: 16-bit
Format: Decimal
Settings: The area number of E-cam when E-cam engaged.
P5-86■
ECAX E-CAM: Master Axis Position
Operational
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Format: Decimal
Settings: The position counter of the E-Cam Master
NOTE
Revision February, 2017
Panel / Software
PR
Unit: -
NOTE
Panel / Software
PR
Unit: -
1. This parameter can be wrote when E-Cam stops (Please refer
toP5-88, X=0).
2. A2L does not support E-Cam function.
Communication
A2L does not support E-Cam function.
Communication
Chapter 8 Parameters
Address: 05AAH
05ABH
Related Section:
7.11
Address: 05ACH
05ADH
Related Section:
7.11
8-203