Delta ASD-A2 Series User Manual page 428

Table of Contents

Advertisement

ASDA-A2
P5-36
CAST CAPTURE - Start Address of Data Array
Operational
Interface:
Default: 0
Control
Mode:
Range: 0 ~ (value set by P5-10 minus 1)
Data Size: 16-bit
Format: Decimal
Settings: The first data CAPTURE obtained should be saved in the address of
NOTE
P5-37■
CAAX CAPTURE-Axis Position CNT
Operational
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Format: Decimal
Settings: Shows the axis position of CAPTURE pulse source
NOTE
Revision February, 2017
Panel / Software
ALL
Unit: -
data array.
It is writable only when COMPARE stops (please refer to P5-39)
Panel / Software
ALL
Unit: -
1)It is writable only when COMPARE stops (please refer to P5-39)
2)If the source is the main encoder, this parameter is write-protected
and the content is the feedback position of the motor (monitoring
variable 00h).
Communication
Communication
Chapter 8 Parameters
Address: 0548H
0549H
Related Section:
7.11.1
Address: 054AH
054BH
Related Section:
7.11.1
8-177