Chapter 10 Troubleshooting
AL209:Parameter number of PR#8 is out of the range
Causes
The parameter number of
command source
exceeds the range
AL213 ~ AL217:An error occurs when writing parameter via PR
Causes
PR commands TYPE 8
Error occurs when writing
parameters
AL231:The setting of monitor item of PR#8 is out of the range
Causes
The monitor item of the
command source
exceeds the range
AL235:PR command overflows
Causes
PR command error
Revision February, 2017
range
Checking Method
Writing parameter via PR
procedure: The parameter number
of command source exceeds the
range
Checking Method
AL213:parameter exceeds the
range
AL215:the parameter is read-only
AL217:Servo On or invalid value
Checking Method
Writing parameter via PR
procedure: The monitor item
number of command source
exceeds the range
Checking Method
Incremental type:
PR mode continuously operates in
one direction and causes feedback
register (FB_PUU) overflows. And
the coordinate system cannot reflect
the correct position. If issuing the
absolute positioning command at
this time, the error will occur.
Absolute type:
The error occurs in following
situations:
1. Feedback register (FB_PUU)
overflows
2. After P1.01.Z is modified, the
system neither returns to the
original point nor conducts
homing procedure.
3.
It does not conduct homing
procedure after the E-gear ratio
is modified (P1-44 and P1-45).
4. Returning to the original point is
Corrective Actions
DI.Alm Reset or write 0 into P0-01
Corrective Actions
DI.Alm Reset or P0-01 = 0
Re-adjust PR command and
parameters
Corrective Actions
DI.Alm Reset or write 0 into P0-01
Corrective Actions
Conduct homing procedure
ASDA-A2