Delta ASD-A2 Series User Manual page 339

Table of Contents

Advertisement

Chapter 8 Parameters
P1-76
AMSPD
Operational
Interface:
Default: 5500
Control
Mode:
Range: 0 ~ 6000
Data Size: 16-bit
Format: Decimal
Settings: According to the real application, this parameter is set for the maximum
P1-77 ~
Reserved
P1-80
P1-81
VCM2 Max. Speed of 2
Operational
Interface:
Default: Motor rated speed
Control
Mode:
Range: 0 ~ 50000
Data Size: 32-bit
Format: Decimal
Settings: Please refer to the description of P1-40.
8-88
Maximum Rotation of Encoder Output Setting
(OA, OB)
Panel / Software
ALL
Unit: r/min
speed and the servo drive will generate smooth function automatically
for encoder output signals.
When the value is set to 0, the function is disabled.
nd
Panel / Software
S/T
Unit: rpm/10V
Communication
Analog Speed Command
Communication
ASDA-A2
Address: 0198H
0199H
Related Section:
P1-46
Address: 01A2H
01A3H
Related Section:
P1-40
Revision February, 2017