Chapter 7 Motion Control
Lead Pulse
Monitoring
Variables
(061)
Disengage
Condition
P5-88.U
Auxiliary
Selection
P5-88.BA
Revision February, 2017
In pre-engaged status, the lead pulse is the moving distance of
master axis before the E-cam is engaged (path
decreases when input the master pulse. When the value is 0, it
enters Engaged status.
Enter Pre-engaged status via path 1, the lead pulse is determined
by the value of P5-87.
Enter Pre-engaged status via path 4, the lead pulse is determined
by the value of P5-92.
If the setting is 0, it means no lead pulse and will enter Engaged
status immediately.
Symbol +/- represents the direction of lead pulse. Please note that
the E-cam will be unable to engage if setting the wrong direction.
If setting the wrong direction, the value of monitoring variable (061) will
increase, which is far from 0 and causes overflow at the end. If it
overflows, the E-cam function will be disabled (P5-88.X=0) and the E-
cam will be forced to return to Stop status.
When the E-cam is in Engaged status, the method of determine
disengaged is as the following:
Note: 2, 4 and 6 cannot be selected at the same time
U
Disengage Condition
Never disengaged. It will be forced to
0
disengage until P5-88.X is set to 0.
1
DI.CAM is OFF
Master axis receives the pulse
number which is set by P5-89 and
2
stops immediately. (The symbol
represents the direction)
Same as 2, the E-cam starts to
decelerate when disengaging. It is
6
suitable for the application of calling
the next PR position command right
after disengaged.
Master axis receives the pulse
number which is set by P5-89 and
4
stops immediately. (The symbol
represents the direction)
8
Disable the E-cam after disengaging
When the E-cam disengaged, if it is in the setting distance (P5-
88.U=2), it returns to Stop status and can determine the execution PR
number.
ASDA-A2
3).
Its value
After Disengaged
(Path 5)
Enter Stop Status
(Path 5)
Enter Stop Status
(Path 5)
Enter Stop Status
(Path 4)
Returns to Pre-
engage Status
The lead pulse is
P5-92
Set P5-88.X=0