ASDA-A2
P1-14
TQ3
Operational
Interface:
Default: 100
Control
Mode:
Range: -300 ~ +300
Data Size: 16-bit
Format: Decimal
Example: Internal Torque Command: 30 = 30 %
Settings: Internal Torque Command 3: The setting of the third internal torque
P1-15
CXFT
Operational
Interface:
Default: 0000h
Control
Mode:
Range: 0000h ~ 0x1F5F
Data Size: 16-bit
Format: Hexadecimal
Revision February, 2017
Internal Torque Command 3/Internal Torque
Limit 3
Panel / Software
T/P, S
Unit: %
Internal Torque Limit: Positive value and
negative value is the same. Please refer to
the following description.
command
Internal Torque Limit 3: The setting of the third internal torque limit
Example of inputting internal torque limit:
Torque limit setting
value of P1-14
30
-30
Capture Synchronous Axis – Threshold of
Correction
Panel / Software
ALL
Unit: -
Communication
Allowable
Forward
Torque Range
Torque Limit
-30 ~ 30 %
Communication
Chapter 8 Parameters
Address: 011CH
011DH
Related Section:
6.4.1
Reverse
Torque Limit
30 %
-30 %
Address: 011EH
011FH
Related Section:
8-53