There are two sets of auto resonance suppression, one is P2-43 and P2-44 and another one is P2-
45 and P2-46. When the resonance occurs, set P2-47 to 1 or 2 (enable the function of resonance
suppression), the servo drive searches the point of resonance frequency and suppresses the
resonance automatically. Write the point of frequency into P2-43 and P2-45 and write the
attenuation rate into P2-44 and P2-46. When P2-47 is set to 1, the system will set P2-47 to 0
(disable the function of auto suppression) automatically after completing resonance suppression
and the system is stable for 20 minutes. When P2-47 is set to 2, the system will keep searching the
point of resonance.
When P2-47 is set to 1 or 2, but resonance still exists, please confirm the value of parameter P2-
44 and P2-46. If one of them is 32, it is suggested to reduce the speed bandwidth first and then
start to estimate again. If the value of both is smaller than 32 and resonance still exists, please set
P2-47 to 0 first and then manually increase the value of P2-44 and P2-46. It is suggested to reduce
the bandwidth if the resonance has not been improved. Then use the function of auto resonance
suppression.
When manually increase the value of P2-44 and P2-46, please check if the value of both is bigger
than 0. If yes, it means the frequency point of P2-43 and P2-45 is the one searched by auto
resonance suppression. If the value of both is 0, it means the default, 1000 of P2-43 and P2-45 is
not the one searched by auto resonance suppression. Deepen the resonance suppression
attenuation rate might worsen the situation.
Current Value
0
0
1
1
1
2
2
2
Revision February, 2017
Settings of P2-47
Desired Value
Clear the setting value of P2-43 ~ P2-46 and enable
1
auto resonance suppression function.
Clear the setting value of P2-43 ~ P2-46 and enable
2
auto resonance suppression function.
Save the setting value of P2-43 ~ P2-46 and disable
0
auto resonance suppression function.
Clear the setting value of P2-43 ~ P2-46 and enable
1
auto resonance suppression function.
Do not clear the setting value of P2-43 ~ P2-46 and
2
enable
continuously.
Save the setting value of P2-43 ~ P2-46 and disable
0
auto resonance suppression function.
Clear the setting value of P2-43 ~ P2-46 and enable
1
auto resonance suppression function.
Do not clear the setting value of P2-43 ~ P2-46 and
2
enable
continuously.
Chapter 6 Control Mode of Operation
Function
auto
resonance
auto
resonance
suppression
function
suppression
function
6-41