Delta ASD-A2 Series User Manual page 356

Table of Contents

Advertisement

ASDA-A2
Data Size: 16-bit
Format: Decimal
Example: 15 = 150 ms
Settings: It is for switching the smooth gain. (0: disable this function)
P2-29
GPE
Operational
Interface:
Default: 1280000
Control
Mode:
Range: 0 ~ 3840000
Data Size: 32-bit
Format: Decimal
Settings: The setting of gain switching (Pulse error, Kpps, r/min) is determined
P2-30■
INH
Operational
Interface:
Default: 0
Control
Mode:
Range: -8 ~ +8
Data Size: 16-bit
Format: Decimal
Revision February, 2017
Gain Switching
Panel / Software
ALL
Unit: Pulse, Kpps, r/min
by the selection of gain switching (P2-27).
Auxiliary Function
Panel / Software
ALL
Unit: -
Communication
Communication
Chapter 8 Parameters
Address: 023AH
023BH
Related Section: -
Address: 023CH
023DH
Related Section: -
8-105