ASDA-A2
Settings: The setting value of the second low-frequency vibration suppression. If
P1-28
VSG2 Low-frequency Vibration Suppression Gain (2)
Operational
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0 ~ 9 (0: Disable the second low-frequency
Data Size: 16-bit
Format: Decimal
Settings: The second low-frequency vibration suppression gain. The bigger value
Revision February, 2017
P1-28 is set to 0, then it will disable the second low-frequency filter.
Panel / Software
Communication
PT / PR
filter)
it is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested to
set the value to 1.
Chapter 6 Control Mode of Operation
Address: 0138H
0139H
Related Section:
6.2.9
6-23