Chapter 8 Parameters
P5-38■
CANO CAPTURE-The Number of Capturing Times
Operational
Interface:
Default: 1
Control
Mode:
Range: 1 ~ (the value set by P5-10 minus the value
Data Size: 16-bit
Format: Decimal
Settings: When CAP stops, it means the number of data that expect to capture
NOTE
P5-39■
CACT CAPTURE-Activate CAP Control
Operational
Interface:
Default: 0x2010
Control
Mode:
Range: 0x0000 ~ 0xF13F
Data Size: 16-bit
Format: Hexadecimal
8-178
Panel / Software
ALL
Unit: -
set by P5-36)
(readable and writable)
When CAP activates, it means the number of data that has not been
captured (read-only); Every time, when it captures one data, the value
of P5-38 will minus one. When the value is 0, it means the capturing is
completed.
1. The number of data which is used by COMPARE, CAPTURE and
E-Cam cannot exceed 800.
2. A2L does not support E-Cam function.
Panel / Software
ALL
Unit: -
Communication
Communication
ASDA-A2
Address: 054CH
054DH
Related Section:
7.11.1
Address: 054EH
054FH
Related Section:
7.11.1
Revision February, 2017