Delta ASD-A2 Series User Manual page 472

Table of Contents

Advertisement

ASDA-A2
Monitoring variable 062(3Eh): It displays the current engaged position (X) of master
axis (X)
This macro command calculates the moving distance between current and target
engaged position (X) and writes into the specified PR.
During E-Cam operation, if users desire to move the slave axis to the specified
position when master axis stops and still in engaged status, this macro command
can calculates the correct moving distance (Y_Drift) of going trip for PR positioning.
When master axis resumes the operation, use another PR to run the moving
distance of return trip (-Y_Drift), it can back to the original position (moving
distance of going trip + moving distance of return trip = 0). E-Cam position remains
the same.
Note: PR command must be the incremental command, regardless in going trip or
return trip.
When E-Cam moves from current position to the target one, it can rotate at forward
or reverse position. Due to the cyclic operation, it can reach the target position
either at forward or reverse direction. However, the moving distance between both
is usually different. Use available forward rate to plan the timing of forward and
reverse rotation.
Revision February, 2017
P5-93.Hi_Word = it has to be set to 0
P5-95 (Available forward rate) = 0 ~ 100 (%)
P5-96 (target positionX); Unit: pulse number of master axis =
0 ~ (P5-84/P5-83) - 1
*Available forward rate: The available max. proportion of forward path
Chapter 8 Parameters
8-221