Chapter 8 Parameters
Range: 1 ~ 1000
Data Size: 16-bit
Format: Decimal
Settings: The smooth constant of analog position command is only effective to
P1-66
PCM
Operational
Interface:
Default: 1.0
Control Mode: PT
Data Size: 16-bit
Format: One decimal
Example: 1.5 = 1.5 cycles
Settings: It is the rotation number setting when analog speed command
P1-67
Reserved
P1-68
PFLT2 Position Command Moving Filter
Operational
Interface:
Default: 4
Control
Mode:
Range: 0 ~ 100
8-84
analog position command.
Max. Rotation Number of Analog Position
Command
Panel / Software
Unit: 1 cycle
Range: 0.0 ~ 200.0
inputs the max. voltage (10V). If it is set to 30 and the external
voltage inputs 10V, it means the position command is +3 cycles. 5V
means the speed control command is 1.5 cycles.
-10V means the position command is -3 cycles.
Position control command = Input voltage value x Setting value/10
It will be available after firmware version v1.031 sub8.
NOTE
Panel / Software
PT/PR
Unit: ms
Communication
10
0.1 cycle
0 ~ 2000
DEC
15 = 1.5 cycles
Communication
ASDA-A2
Address: 0184H
0185H
Related Section: -
Address: 0188H
0189H
Related Section: -