Chapter 6 Control Mode of Operation
P1-03
AOUT Polarity Setting of Encoder Pulse Output
Operational
Interface:
Default: 0
Control
Mode:
Unit: -
Range: 0 ~ 0x13
Data Size: 16-bit
Format: Hecimal
Settings:
6-54
Please refer to parameter P1-04, P1-05 for proportional setting of
NOTE
analog output voltage.
For example: P0-03 = 01 (MON1 is the analog output of motor
speed; MON2 is the analog output of motor torque (force))
MON1 output voltage
MON2 output voltage
(unit: Volts)
Panel / Software
ALL
Polarity of monitor analog output
0: MON1(+), MON2(+)
1: MON1(+), MON2(-)
2: MON1(-), MON2(+)
3: MON1(-), MON2(-)
Polarity of encoder pulse output
0: Forward output
1: Reverse output
8
.
8
.
Communication
Polarity of monitor analog output
Polarity of encoder pulse output
Not in use
ASDA-A2
(unit:Volts)
Address: 0106H
0107H
Related Section: