Delta ASD-A2 Series User Manual page 395

Table of Contents

Advertisement

Chapter 8 Parameters
P3-11
CANOP CANopen / DMCNET Selection
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: Shown as below
Data Size: 16-bit
Format: Hexadecimal
Settings: Synchronous / DMCNET setting of CANopen is divided into X, Y, Z and
NOTE
P3-12
QSTPO CANopen / DMCNET Support Setting
Operational
Interface:
Default: 0x0000
Control
Mode:
Range: 0x0000 ~ 0x0111
Data Size: 16-bit
Format: Hexadecimal
8-144
Panel / Software
CANopen / DMCNET
Unit: -
U (hexadecimal):
Item
Function
Undefined
Range
The definition is as follows:
X = 1: When writing parameters via PDO, parameters will be saved in
EEPROM.
X = 0: When writing parameters via PDO, parameters will not be saved
in EEPROM.
Y, Z, U : Undefined
If X is set to 1 and write parameters by PDO continuously, it will
shorten the lifetime of EEPROM.
Panel / Software
CANopen / DMCNET
Unit: -
Communication
U
Z
Undefined
-0 ~ 1
0 ~ F
Communication
Address: 0316H
Related Section:
Section 9.2
Y
X
Whether the
Undefined
parameter is saved
into EEPROM
0 ~ F
0 ~ 1
Address: 0318H
Related Section:
Section 9.2
Revision February, 2017
ASDA-A2
0317H
0319H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents