Delta ASD-A2 Series User Manual page 351

Table of Contents

Advertisement

Chapter 8 Parameters
P2-19
DO2
Operational
Interface:
Default: 103
Control
Mode:
Range: 0 ~ 0x013F (the last two codes are DO code)
Data Size: 16-bit
Format: Hexadecimal
Settings: Please refer to the description of P2-18
P2-20
DO3
Operational
Interface:
Default: 109
Control
Mode:
Range: 0 ~ 0x013F (the last two codes are DO code)
Data Size: 16-bit
Format: Hexadecimal
Settings: Please refer to the description of P2-18
8-100
Output function selection: Please refer to table 8.2
Output contact: a or b contact
0: Set the output contact as normally closed (b contact)
1: Set the output contact as normally opened (a contact)
(P2-18 ~ P2-22) The setting value of function programmed
When parameters are modified, please re-start the servo drive to
ensure it can work normally.
DO2 Functional Planning
Panel / Software
ALL
Unit: -
DO3 Functional Planning
Panel / Software
ALL
Unit: -
Communication
Communication
ASDA-A2
Address: 0226H
0227H
Related Section:
Table 8.2
Address: 0228H
0229H
Related Section:
Table 8.2
Revision February, 2017