Chapter 8 Parameters
P6-01
ODAT Origin Definition
Operational
Interface:
Default: 0
Control
Mode:
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Format: Decimal
Settings: Value of origin definition:
P6-02
PDEF1 PATH#1 Definition
Operational
Interface:
Default: 0x00000000
Control
Mode:
Range: 0x00000000 ~ 0xFFFFFFFF
Data Size: 32-bit
Format: Hexadecimal
8-226
If it does not return to the origin, set PATH to 0.
If it needs to return to the origin, set PATH to non-zero value and
set PABS = ORG_DEF.
B. If the origin is found (Sensor or Z), desire to move an offset S and
define the coordinate as P after moving, then PATH = non-zero and
set ORG_DEF = P-S. The absolute position command = P.
Panel / Software
PR
Unit: -
.31 ~
.27 ~
28
24
Panel / Software
PR
Unit: -
Communication
.23
.19 ~
.15 ~
~20
16
12
ORG_DEF (32-bit)
Communication
ASDA-A2
Address: 0602H
0603H
Related Section:
7.10
11 ~ 8
7 ~ 4
3 ~ 0
Address: 0604H
0605H
Related Section:
7.10
Revision February, 2017