Chapter 6 Control Mode of Operation
P1-36
TSL
Operational
Interface:
Default: 0
Control
Mode:
Unit: ms
Range: 0 ~ 65500 (0: disable this function)
Data Size: 16-bit
Format: Decimal
Settings: Acceleration / Deceleration Constant of S-Curve:
NOTE
Analog Speed Command Filter
Analog speed command filter is provided especially for ASDA-A2 series users. It mainly helps with
buffer when the analog input signal changes too fast.
6-28
Acceleration / Deceleration Constant of S-
Curve
Panel / Software
S, PR
P1-34: Set the acceleration time of acceleration / deceleration of
trapezoid-curve
P1-35: Set the deceleration time of acceleration / deceleration of
trapezoid-curve
P1-36: Set the smoothing time of S-curve acceleration and
deceleration
P1-34, P1-35 and P1-36 can be set individually. Even when P1-36 is
set to 0, it still has acceleration / deceleration of trapezoid-curve.
1)When the source of speed command is analog, and P1-36 is set to
0, it will disable S-curve function.
2)When the source of speed command is analog, the max. range of
P1-36 will be set within 10000 automatically.
Communication
ASDA-A2
Address: 0148H
0149H