Chapter 8 Parameters
Example: Internal Torque Command: 30 = 30 %
Settings:
P1-13
TQ2
Operational
Interface:
Default: 100
Control
Mode:
Range: -300 ~ +300
Data Size: 16-bit
Format: Decimal
Example: Internal Torque Command: 30 = 30 %
Settings: Internal Torque Command 2: The setting of the second internal torque
8-52
Internal Torque Limit: Positive value and
negative value is the same. Please refer to
the following description.
Internal Torque Command 1: The setting of the first internal torque
command
Internal Torque Limit 1: The setting of the first internal torque limit
Example of inputting internal torque limit:
Torque limit
setting value
of P1-12
30
-30
Internal Torque Command 2/Internal Torque
Limit 2
Panel / Software
T/P, S
Unit: %
Internal Torque Limit: Positive value and
negative value is the same. Please refer to
the following description.
command
Internal Torque Limit 2: The setting of the second internal torque limit
Example of inputting internal torque limit:
Torque limit setting
value of P1-13
30
-30
Allowable
Forward Torque
Torque Range
Limit
-30 ~ 30 %
Communication
Allowable
Torque Range
-30 ~ 30 %
Reverse Torque
Limit
30 %
-30 %
Address: 011AH
011BH
Related Section:
6.4.1
Forward
Reverse
Torque Limit
Torque Limit
30 %
-30 %