P1-35
TDEC Deceleration Constant of S-Curve
Operational
Interface:
Default: 200
Control
Mode:
Unit: ms
Range: 1 ~ 65500
Data Size: 16-bit
Format: Decimal
Settings: Deceleration Constant of Rotary Motor:
NOTE
P1-36
TSL
Operational
Interface:
Default: 0
Control
Mode:
Unit: ms
Range: 0 ~ 65500 (0: disable this function)
Data Size: 16-bit
Format: Decimal
Revision February, 2017
Panel / Software
S
The time that speed command decelerates from the rated speed to 0.
Deceleration Constant of Linear Motor:
The time that speed command decelerates from 5m/s to 0.
P1-34, P1-35 and P1-36, the deceleration time of speed command
from the rated speed to zero, all can be set individually. Even when P1-
36 is set to 0, it still has acceleration / deceleration of trapezoid-curve.
1)When the source of speed command is analog, and P1-36 is set to
0, it will disable S-curve function.
2)When the source of speed command is analog, the max. range of
P1-35 will be set within 20000 automatically.
Acceleration / Deceleration Constant of S-
Curve