Delta ASD-A2 Series User Manual page 302

Table of Contents

Advertisement

ASDA-A2
P1-11
SP3
Operational
Interface:
Default: 3000
Control
Mode:
Range: -60000 ~ +60000
Data Size: 32-bit
Format: Decimal
Example: Internal Speed Command:
Settings: Internal Speed Command 3: The setting of the third internal speed
P1-12
TQ1
Operational
Interface:
Default: 100
Control
Mode:
Range: -300 ~ +300
Data Size: 16-bit
Format: Decimal
Revision February, 2017
Internal Speed Command 3/Internal Speed
Limit 3
Panel / Software
S/T
Unit: 0.1rpm
120 = 12 r/min
Internal Speed limit: Positive value and
negative value is the same. Please refer to
the following description.
command
Internal Speed Limit 3: The setting of the third internal speed limit
Example of inputting internal speed limit:
Speed limit
setting of P1-11
1000
-1000
Internal Torque Command 1/Internal Torque
Limit 1
Panel / Software
T/P, S
Unit: %
Communication
Allowable Speed
Forward Speed
Range
Limit
-100 ~ 100 r/min
Communication
Chapter 8 Parameters
Address: 0116H
0117H
Related Section:
6.3.1
Reverse
Speed Limit
100 r/min
-100 r/min
Address: 0118H
0119H
Related Section:
6.4.1
8-51