3.5.7 Network connections on OmniCore
Connections on the OmniCore controller
The following figure illustrates the available Ethernet port connectors on the
controller.
1
xx1800003138
1
2
3
4
A factory wide I/O network should be connected to the Ethernet port WAN on the
controller.
Product manual - OmniCore C90XT
3HAC073706-001 Revision: E
Note
For information regarding location of the Ethernet port connectors, see
Connectors on the OmniCore C90XT controller on page
1
Label
I/O + LAN + ETHERNET
SWITCH
ABB Ability™
WAN
MGMT (Management)
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Network connections on OmniCore
64.
2
Description
Port to the robot's private network. Intended for
connecting ABB Scalable I/O units and network
based process equipment to the controller.
This port only exists if the wired variant of the Con-
nected Services Gateway is used. Intended for
connecting to the robot's Ability™ network.
WAN port that can be used to host a public industri-
al network.
Port to the robot's private network. The MGMT port
shall be used by service personnel in close proxim-
ity to the controller, with a single client connected
to the controller.
Note
The management port shall never be used for more
than one client at a time. ABB Robotics assumes
no responsibility for any errors/hazards that may
appear when more than one client is attached to
the management port.
Continues on next page
3
1
4
81